Tested, Proven and Reliable Surge Protection — Only With Empower
Empower True Series Mode™ circuitry is universally recognized as the ultimate in surge suppression.
And because it’s non-current-limiting, it allows power amplifiers to replicate fast energy transients across
the full dynamic range of the system — while providing certified A-1-1 protection for your valuable investment.
With Empower, there is no tradeoff between protection and performance.
|
| SPECIFICATIONS |
EM1100 & EM2100 |
EM510 |
| Load Rating |
15 amps @ 120 volts |
20 amps @ 120 volts |
| UL 1449-2 Adjunct Classification Test Results |
1000 surges, 6000 volts, 3000 amps, C1 pulse. Measured suppressed voltage is 290 volts. No failures |
| U.S. Federal Guidelines |
All models meet Grade A, Class 1, Mode 1 surge suppression guidelines |
| Clamping Voltage Onset |
172 volts nominal (2 volts above peak line voltage, auto-tracking). |
| Filter (bi-directional, wave tracking, with 50 ohm load) |
3 dB @ 3 kHz; 38 dB @ 100 kHz; 50 dB @ 300 kHz; 50 dB @ 5 MHz; 50 dB @ 30 MHz |
| Maximum Applied Surge Pulse Joule Rating |
Unlimited (8 x 20 µs). |
| Maximum Applied Surge Pulse Voltage |
6000 volts (1.2 x 50 µs pulse), industry standard rating |
| Maximum Applied Surge Pulse Current |
100,000 amperes (8 x 20 µs) |
| Endurance, IEEE C62.41-1991 Category B3 (C1) Pulses |
1 kv>500,000; 3 kv>10,000; 6 kv>1000 |
Empower products are designed and manufactured in the U.S.A. Empower, True Series Mode, ICE (Inrush Current Elimination), and Impedance Tolerant are trademarks of New Frontier Electronics Inc.
|
|